Data Center Monitoring

A data center is a facility used to house networked computer servers and storage systems that are securely connected to the Internet. A data center generally includes redundant or backup power supplies, redundant data communications connections, environmental controls (e.g., air conditioning, gas detection, fire suppression), and physical access control systems.

Large data centers are industrial scale operations using as much electricity as a small town and therefore facilities managers must look for ways to be more energy efficient without compromising the operation of the data center. Facility managers must also implement various systems to ensure that the assets and the personnel working in the data center are protected from potentially hazardous conditions like gas and fire. The facility management system or features are often integrated with the facility’s Data Center Information Management (DCIM) system.

Energy Management and Other Facility Automation

DCIM systems collect a lot of data from the typical electronic systems in the data center, often through SNMP based collection schemes. However, a data center also uses many devices used in generic building management such as electric sub-meters, HVAC-specific sensors, and physical access control systems. These devices or subsystems, typically running on BACnet and Modbus protocols, need to be integrated into the data center's or larger facility's Building Management System (BMS), and they also need to feed into the DCIM system so that the DCIM dashboard can offer a holistic view of the health of the data center.

As data centers continue to evolve, integrating a variety of BACnet and Modbus devices used within a data center facility to a BMS and/or DCIM system becomes important to centralizing access and reducing ongoing costs related to data center production, such as power and cooling. Through the DCIM system, facility managers can monitor real-time device information and benefit from integrated monitoring, ticketing, and reporting for better accuracy and speed. Facility managers can also adjust temperature and humidity levels to control energy usage within the data center through the DCIM.

As data center facility managers look to integrate more BACnet and Modbus devices into a DCIM system to ensure peak monitoring and controlling capabilities, protocol gateways are the key to full interoperability. A protocol gateway capable of translating from any protocol to any other protocol becomes an essential element in a data center blueprint. Within a data center, typical protocol translations from devices to the DCIM include:

  • Modbus to SNMP
    • Modbus RTU to SNMP
    • Modbus TCP/IP to SNMP
  • BACnet to SNMP
    • BACnet/IP to SNMP
    • BACnet MS/TP to SNMP

In addition to protocol translation, a gateway with the ability to represent Modbus devices as a unique SNMP management information base (MIB) to the SNMP-based management system is more valuable than the gateway acting as a single proxy for all of the devices. This grants the integrator granular visibility and control over each Modbus device from a SNMP management system. With the ability to manipulate virtual SNMP devices, reconfiguration of the network (adding or removing devices) becomes extremely simple.

As an example, data centers draw a lot of power and it is an industry standard to have detailed power metering for servers and 19’ racks. With visibility over SNMP virtual nodes, each power meter or power distribution unit (PDU) can be seen as an SNMP device on the Ethernet network, making management of the power demand in a data center on a granular level possible.

Gas Hazards in a Data Center

Back up power in a data center is often provided by batteries or by diesel (or sometimes alternative fuel powered) generators. Lead-acid batteries release hydrogen gas when they are charging, and as a combustible gas, the buildup of hydrogen in the battery room can potentially result in an explosion. Generators, running on diesel fuel, can produce an output that is sufficient enough to cover a data center's electricity demand for a period of time in the event of an electrical outage. The use of diesel fuel can result in Carbon Monoxide as a byproduct. Although good ventilation can generally dispel the gas, if not properly monitored, the buildup of Carbon Monoxide can displace Oxygen within a generator room and create a hazard for personnel.

A gas detection and alarming system that uses appropriate audio, visual, or message based alarms and that is integrated with the larger facility management or DCIM system for mitigation (such as increasing air flow to dispel gas) or analytics is the best practice.

Products for Data Center Monitoring

Sierra Monitor’s FieldServer protocol converters and gateways contain over 140 different protocols to enable interoperability between various devices, the BMS, and the DCIM system. Forward-looking data center managers generally anticipate the need for integration and specify protocol gateways as part of their standard data center blueprint. Integrators responding to the specification value the flexibility and ease-of-use offered by the FieldServer protocol gateways because it allows them to complete their integration projects quickly and with low risk. OEMs who target the data center can embed the FieldServer protocol gateways with their products as it enables them to become “multi-protocol” aware (without increasing their R&D costs), so they can bid on integration-heavy data center projects.

FieldServer Solutions

Additionally Sierra Monitor also offers its Sentry IT solution – a comprehensive Nationally Recognized Testing Lab (NRTL) approved gas detection system that is appropriate for measuring H2 or CO build up from the battery banks and generators in the data center. Sentry IT detectors and controllers offer the industry's best Return on Investment (ROI) to the facility manager through innovations that minimize installation, commissioning, calibration, and life cycle maintenance costs. Moreover, the Sierra Monitor products are more analytics capable and integration-friendly than alternate solutions.